AI data centres

Fire resistance of prefabricated data centre modules and containers — walls, roofs, doors, joints — to UL 263, ASTM E119, UL 10C and EN standards, plus battery and explosion testing for the energy storage that powers them.

Why fire resistance is now a data centre question

AI training and inference capacity is being built fast, much of it in prefabricated modules and containers that ship complete from the factory. Two things follow:

  • Modules are regulated as buildings. UL 2755 covers modular data centres, and many jurisdictions treat occupiable data centre containers as buildings. Their walls, roofs and doors then need hourly fire resistance ratings.
  • Energy storage sits next door. Large battery systems are installed alongside AI data centres. The enclosure has to keep a neighbouring battery fire out — or justify the spacing that does.

We have already completed a large number of fire resistance projects for AI data centre enclosures.

What we test

ElementStandards
Wall and roof panels, including jointsUL 263, ASTM E119, EN 1363 / 1364, ISO 834
DoorsUL 10C / UL 10B, EN 1634-1
Insulation, linings, cableEN 13823 and Euroclass tests, UL 94, IEC 60332
Battery systems on siteUL 9540A, large-scale fire tests

Our approach

We start from the requirement — which market, which authority, which rating — and design the specimen around the weakest details: joints, penetrations, door frames. Simulation and indicative tests come before the certification test, so the expensive test is run once.

Related services

Test Test

Fire resistance of BESS enclosures and data centre modules

Fire resistance tests of the walls, roofs, doors and joints of battery energy storage enclosures and prefabricated data centre modules — to UL 263, ASTM E119, UL 10C, EN 1363/1364, EN 1634-1 and ISO 834 — for markets that treat these boxes as buildings.

Learn more

Fire resistance testing of building assemblies

Hourly fire resistance tests of walls, partitions, floors, roofs, ceilings and beams to UL 263, ASTM E119, EN 1363/1364/1365, ISO 834, BS 476 and AS 1530.4, in vertical and horizontal furnaces, under CNAS accreditation.

Learn more

Fire door testing for export (UL 10B, UL 10C, EN 1634-1)

Fire resistance tests of door assemblies, shutters and openable windows for North America, Europe and ISO markets — with indicative tests and failure analysis so the certification test passes the first time.

Learn more

Reaction-to-fire testing of materials

Euroclass testing (EN 13823 SBI, EN ISO 1182, 1716, 11925-2, 9239-1), UL 94 for plastics, IEC 60332 for cables, UL 2043 for plenum products and IMO FTP Code for marine materials.

Learn more

Battery thermal runaway testing (UL 9540A, UL 9540B)

Cell, module and unit level UL 9540A tests within our CNAS scope, UL 9540B for residential systems, and the gas flammability and explosion data that NFPA 68 and NFPA 69 designs need.

Learn more

Large-scale fire testing of energy storage systems

Full-size fire tests of outdoor cabinets and BESS containers up to 20–40 MW peak heat release: open-door or closed-door, with or without suppression, with adjacent target units — to answer what happens when a unit is fully involved in fire.

Learn more