Large-scale fire testing of energy storage systems

Full-size fire tests of outdoor cabinets and BESS containers up to 20–40 MW peak heat release: open-door or closed-door, with or without suppression, with adjacent target units — to answer what happens when a unit is fully involved in fire.

Large-scale fire testing of energy storage systems

Why large-scale fire tests

UL 9540A shows whether thermal runaway propagates. It does not always produce a fully developed fire. Regulators and insurers increasingly want to see the worst case: a unit fully involved in fire, and whether the fire spreads to adjacent units, equipment or through a fire-rated barrier. Manufacturers also use these tests to prove passive fire protection — barriers, insulation, enclosure design — before going to market.

What we build

  • Initiating unit with thermal runaway triggered by heaters and the vent gas ignited by a controlled igniter.
  • Target units at the spacing you want to prove — side by side, back to back or across an aisle.
  • Scenarios: doors open or closed, suppression on or off, full state of charge, extended burn duration.

What we measure

Heat release by calorimetry under the exhaust hood; up to 180 temperature channels; radiant heat flux on target units; pressure; O₂, CO, CO₂, H₂ and FTIR gas analysis, with gas samples for later GC-MS; HD, thermal and high-speed video; and fire water sampling for analysis.

Our two large-scale sites

Hebei large-scale fire test siteJiading indoor fire hall
TypeOutdoor, mountain valleyIndoor
Exhaust hood18 m × 13 m, 17 m above ground25 m × 25 m, 25 m high
Scale10–20 MW cabinets, 20–40 MW containers20 MW
Typical useBESS containers and cabinetsC&I energy storage, electric vehicles

Plan it with simulation

A large-scale burn costs a full system. We use fire and explosion simulation to predict the outcome, choose the scenario and set the test up to answer the question you actually need answered.

Deliverables

  • Test plan agreed with you and, where needed, your certifier or AHJ
  • Test report with heat release, temperatures, heat flux, gas and video records
  • Remote live viewing for your team and witnesses
  • Post-test engineering review: what happened, why, and what to change

Frequently asked questions

What is the difference between an open-door and a closed-door burn?

A closed-door burn keeps the container closed and relies on its ventilation and explosion vents, as designed to NFPA 68/69. An open-door burn opens the doors to give the fire unlimited air and relies only on passive fire protection. They answer different questions; we help you choose. See our article on the subject.

How big a system can you burn?

The Hebei site is built for outdoor cabinets with an estimated peak heat release of 10–20 MW and containers of 20–40 MW, with a 60 t crane. The Jiading indoor hall is rated at 20 MW.

Can we watch remotely?

Yes. The Hebei site streams test data and video to an observation room about 800 m away and to remote participants.

Talk to an engineer

Tell us what you need to test

Describe the product, target market and standards. An engineer will get back to you shortly.