12 Dec 2025 · Huahui Fire technical team

Congratulations to Trina Storage on a successful large-scale fire test of Elementa 2Pro

Trina Storage's in-house Elementa 2Pro 5 MWh energy storage system has completed a large-scale fire test under extreme conditions, fully charged and fully configured, with Huahui Fire providing the test site and technical services.

Trina Storage's in-house Elementa 2Pro 5 MWh energy storage system has recently completed a large-scale fire test under extreme conditions, fully charged and fully configured.

The whole test was witnessed jointly by the international certification body TÜV Rheinland and the North American fire consultancy Hiller. It met the requirements of the latest international safety standards, NFPA 855-2026 and UL 9540A, and was carried out under verification conditions more severe than the standards require.

As a TÜV Rheinland partner laboratory, Huahui Fire provided specialist site support and technical services for the test, helping Trina Storage complete this demanding test and fully demonstrating the leading system-level safety of Elementa 2Pro.

Safety verified under extreme conditions

This fire test of the Elementa 2Pro 5 MWh energy storage system not only met the international safety standards NFPA 855-2026 and the edition of UL 9540A published on 9 November 2025, but also went well beyond common industry practice on several key test conditions. It comprehensively simulated the worst case a real power station might face, verifying the product's safety in the most demanding way.

The test design set four core severe conditions aimed squarely at the critical weak points of energy storage safety:

Extreme layout compressing the space for heat dissipation: the back-to-back spacing between units was reduced to just 10 cm, simulating an enclosed environment where heat can hardly escape and testing the system's stability as heat builds up;

Full configuration and full charge for peak risk: the cabin set on fire was held at 100 % SOC (state of charge), and the battery packs at the top of the neighbouring cabins were also fully charged, maximising the intensity of thermal runaway and the likelihood of propagation between cabins;

No external firefighting: active suppression and extinguishing systems were disabled throughout, so the system relied solely on its own structural separation and safety architecture, recreating an extreme crisis with no outside help;

Extra oxygen to intensify burning: the explosion vent panels and the fire ventilation system (supply and exhaust) were opened, significantly increasing the oxygen available, so that the thermal reaction was far more intense than under real site conditions.

The final result was encouraging. Under these severe conditions, the Elementa 2Pro system stayed structurally stable: the triggered cabin did not collapse at all, there was no thermal propagation to the neighbouring cabins, and the system-level thermal insulation and protection design performed exactly as intended. The fire alarm system kept working until the batteries lost power, leaving ample time for people to respond, and after the test the UPS system could still be started normally and the electrical cabinets were undamaged. This fully verifies Trina Storage's safety capability across the whole chain, from cells and modules to system engineering, and sets a new benchmark for "system-level safety verification" in the industry.

Why the test matters

For energy storage manufacturers, a large-scale fire test like this is not a "cost" but a core way of protecting customer value and strengthening competitiveness. Energy storage projects worldwide have entered the GWh era, and customers care more than ever about the safety of their assets and their people.

A fire test under extreme conditions lets manufacturers pin down the safety limits of their products and let the test data speak for themselves. It builds trust with customers, financiers and approving authorities, and it is a prerequisite for entering major international markets: in overseas markets such as North America and the Middle East, large-scale fire testing has become a key precondition for project delivery and financing approval.

The success of this test not only proves the reliability of Trina Storage's products under extreme conditions but also reflects the maturity and reliability of its technology and delivery capability in real projects and operation.

Huahui Fire's support for the test

As a TÜV Rheinland partner laboratory, Huahui Fire drew on its established test sites, advanced equipment and technical services to provide comprehensive specialist support for the Elementa 2Pro large-scale fire test, ensuring that the test was completed smoothly and its results carry authority.

Specialist test site:

The test was carried out at the large-scale fire test laboratory in Baoding, Hebei. The laboratory was built jointly by Huahui Fire and Baoding Aidi Xinneng Testing Technology Co., Ltd. and covers 20 mu (about 13,000 m²), with a core test area of 1000 m². Full-scale burn scenarios can be built there for large energy storage containers, and it is equipped with large-scale calorimetry that can reproduce thermal propagation under complex conditions, meeting the safety testing and certification needs of high-capacity energy storage systems.

Advanced test equipment and techniques:

The test site uses a leading smoke collection system to collect, analyse and clean the gases throughout the test, so that the test causes no environmental pollution. It also has an advanced data acquisition and analysis system that monitors and records key parameters such as temperature, pressure and gas composition in real time, giving a scientific basis for evaluating product performance.

Service throughout:

Huahui Fire provides an end-to-end solution covering scenario design, simulation, multiple stages of verification testing and, finally, the large-scale fire test, supporting the safety design and compliance testing of energy storage products throughout and helping manufacturers verify product safety efficiently.

The Huahui Fire team was involved early, before the test. During the test, our technical staff were on site throughout, working with the certification bodies on data acquisition, equipment set-up and safety supervision, keeping the test on plan.

With the energy storage industry growing fast, safety has become a key constraint on its development. Huahui Fire will continue to work in a professional, rigorous and innovative way, constantly improving its testing capability and technical expertise, to give energy storage companies more comprehensive, more specialised and more efficient testing services.

Whether you need verification testing at cell, module, cabinet/unit or container level, Huahui Fire can provide a tailored test plan and specialist technical support. We aim to be your trusted partner in energy storage safety testing and to advance safety technology across the energy storage industry together.

To find out more about large-scale fire testing of energy storage systems, or to book a test, please get in touch.

Contact us: +86 21 6991 3579, [email protected], or send a test request on this website.

First published on our WeChat channel: read the original

Talk to an engineer

Tell us what you need to test

Describe the product, target market and standards. An engineer will get back to you shortly.