Energy storage and batteries

UL 1487

ANSI/CAN/UL/ULC 1487:2025, Standard for Battery Containment Enclosures (joint US/Canada standard, first edition)

UL 1487 covers enclosures for storing lithium-ion cells, battery packs and battery-powered devices, and tests whether the enclosure contains the heat, fire and deflagration hazards of a battery thermal runaway. We can carry out all its performance tests — endurance cycling, weight loading, internal thermal runaway, internal deflagration and external fire. They are not currently within our accreditation.

Available, outside accreditation scope We can carry out the tests of UL 1487:2025 sections 14 to 17 and Annex D. They are not currently within our CNAS / CMA accreditation, and reports carry no accreditation mark.

What it tests

Factories, warehouses and laboratories often store lithium-ion batteries and power-tool packs in dedicated cabinets. UL 1487, published in February 2025 for the US and Canada, is the first standard specifically for these battery containment enclosures. It addresses three hazards of thermal runaway — heat, fire and deflagration — but not toxicity.

Performance tests:

SectionTestWhat is checked
14Endurance cyclingAfter repeated cycling, self-closing doors, self-closing and self-latching mechanisms, handles and hinges still work as intended
15Weight loadingAfter 72 hours with 120 % of the rated load of inert weights in each storage cavity, doors, shelves, dividers and so on still work
16Internal thermal runawayThermal runaway is initiated in test cell packs inside; no charring or ignition of the cheesecloth indicator, no external flaming, no effluent gas release other than through dedicated vents, and temperatures within limits
17Internal deflagrationA flammable mixture inside is ignited; no rupture, no ejection of fragments, no collapse of storage cavities, and no external flaming except through pressure-relief devices or dedicated vents
Annex DExternal fireOptional: at the request of the manufacturer or authority having jurisdiction, the enclosure's resistance to an external fire

Testing at Huahui

We can carry out all the tests of UL 1487, sections 14 to 17 and Annex D. The internal thermal runaway test runs under a collection hood that captures all effluent gases, smoke and products of combustion. These tests are not currently within our CNAS / CMA accreditation, and reports carry no accreditation mark.

For the heat and abrasion resistance of battery enclosure materials themselves, see UL 2596; for thermal runaway propagation in energy storage systems, see UL 9540A.

Available, not accredited

StandardTest items
ANSI/CAN/UL/ULC 1487:2025
Battery containment enclosures
  • Section 14: endurance cycling test
  • Section 15: weight loading test
  • Section 16: internal thermal runaway test
  • Section 17: internal deflagration test
  • Annex D: external fire test

We can carry out these tests, but they are not currently within our CNAS / CMA accreditation, and reports carry no accreditation mark. If the results are for certification, check first that your certifier accepts them.

Frequently asked questions

How does UL 1487 differ from UL 9540A?

UL 9540A evaluates thermal runaway propagation in an energy storage system itself. UL 1487 evaluates whether an enclosure used to store batteries contains the thermal runaway, fire and deflagration of the batteries inside. UL 1487 explicitly excludes energy storage systems, which fall under UL 9540.

Can the enclosure include charging?

Yes. The standard allows enclosures with integral systems, or with internal power distribution for charging the cells, batteries, packs or battery-powered devices inside.

Talk to an engineer

Tell us what you need to test

Describe the product, target market and standards. An engineer will get back to you shortly.