Chinese standards: fire doors, windows, shutters and glass

GB/T 15763.1

GB/T 15763.1-2025 Safety glass for buildings — Part 1: Fire-resistant glass (《建筑用安全玻璃 第1部分:防火玻璃》)

GB/T 15763.1 is the product standard for fire-resistant glass. It sets requirements for dimensions and thickness, appearance, light transmittance, heat resistance, cold resistance, UV irradiation resistance, impact resistance, fragmentation and fire resistance. Fire resistance of fire-resistant glass is within our CNAS scope; the other items are within our CMA approval scope.

Within CNAS accreditation GB/T 15763.1-2025 clause 7.6 is within our CNAS scope; a number of items in clauses 7.1–7.10 are within our CMA approval scope.

What it measures

Test items for fire-resistant glass include:

  • Fire resistance;
  • Optical properties and appearance: permissible deviations in dimensions and thickness, appearance quality, visible light transmittance;
  • Weathering: heat resistance, cold resistance, UV irradiation resistance;
  • Mechanical properties: impact resistance, fragmentation.

Our CMA scope (CMA is China's mandatory approval for inspection and testing bodies) also includes bow, impact resistance and fragmentation of tempered glass (the tempered glass part of the safety glass for buildings standard).

Testing at Huahui

Tests run at our Shanghai main laboratory. For framed fire-resistant glass elements, see GB/T 12513; for fire windows, see GB 16809.

For the classification of fire-resistant glass and the changes in the new standard, see our articles Fire-resistant glass for buildings explained and New Chinese national standard for fire-resistant glass published.

Our accredited scope

AccreditationStandardTest items
CNAS GB/T 15763.1-2025
Safety glazing materials in buildings — Part 1: Fire-resistant glass
  • Fire resistance (cl. 7.6)
CMA GB/T 15763.1-2025
Safety glazing materials in buildings — Part 1: Fire-resistant glass
  • Dimension and thickness tolerances – Fire-resistant safety glass for buildings (cl. 7.1)
  • Appearance – Fire-resistant safety glass for buildings (cl. 7.2; No separate report for this item)
  • Visible light transmittance – Fire-resistant safety glass for buildings (cl. 7.5)
  • Heat resistance – Fire-resistant safety glass for buildings (cl. 7.6)
  • Cold resistance – Fire-resistant safety glass for buildings (cl. 7.7)
  • UV resistance – Fire-resistant safety glass for buildings (cl. 7.8)
  • Impact resistance – Fire-resistant safety glass for buildings (cl. 7.9)
  • Fragmentation – Fire-resistant safety glass for buildings (cl. 7.10)
  • Bow – Tempered safety glass for buildings (cl. 6.4)
  • Impact resistance – Tempered safety glass for buildings (cl. 6.5)
  • Fragmentation – Tempered safety glass for buildings (cl. 6.6)
  • Appearance – Fire windows (cl. 6.2; Withdrawn edition, kept only as referenced by GB 16809-2008; no separate report)
  • Dimensions and thickness – Fire windows (cl. 6.1; Withdrawn edition, kept only as referenced by GB 16809-2008)
  • Fire resistance (cl. 7.3; Changed to GB/T 15763.1-2025 on 27 July 2026; the new edition took effect on 1 August 2026)

From our CNAS accreditation scope and our CMA approval (China's mandatory approval for inspection and testing bodies, needed for reports used in mainland China), as of 2026-10. Items not listed are outside the scope; ask our engineers whether they can be tested.