What it measures
Glazed elements are partitions, screens and window assemblies that contain glass. The specimen, complete with its glass, frame, seals and fixings, is exposed on a furnace and assessed for integrity and insulation. The performance of the glass itself, the fit between glass and frame, and the behaviour of the sealing strips all affect the result.
Testing at Huahui
Tests run at our Shanghai main laboratory. Within our CMA scope (CMA is China's mandatory approval for inspection and testing bodies), heat flux is not measured. For product testing of the fire-resistant glass itself, see GB/T 15763.1; for fire windows, see GB 16809.
Our accredited scope
| Accreditation | Standard | Test items |
|---|---|---|
| CNAS | GB/T 12513-2026 Fire resistance test methods for glazed elements and window assemblies |
|
| CMA | GB/T 12513-2026 Fire resistance test methods for glazed elements and window assemblies |
|
From our CNAS accreditation scope and our CMA approval (China's mandatory approval for inspection and testing bodies, needed for reports used in mainland China), as of 2026-10. Items not listed are outside the scope; ask our engineers whether they can be tested.