What it tests
UL 72 covers record protection equipment, such as safes, file cabinets and data cabinets used to store documents, records and data media. The core question: after a set time in a standard fire, does the inside get hot enough to damage the contents?
A rating has two parts:
- An interior temperature limit, matched to the records stored:
- 350 °F (177 °C): paper records.
- 150 °F (66 °C): paper records, and electronic data media such as magnetic tapes, and photographic records.
- 125 °F (52 °C): as 150 °F, and also flexible computer disks.
- A duration: 1/2, 1, 2, 3 or 4 hours. The duration includes the cool-down after the fire exposure; the interior must stay below the limit during the cool-down too.
"Class 350, 1 hour", for example, means the interior stays below 177 °C through 1 hour of fire exposure and the cool-down that follows.
The tests in UL 72:
- Fire endurance test (section 6): exposure to the standard fire curve, measuring interior temperature, and also interior humidity for classes 150 and 125.
- Fire and impact test (for equipment intended to resist impact): after fire exposure, a drop from 9.1 m (30 ft), then the sample is inverted and exposed again.
- Explosion test and combined explosion impact test.
- Gasket materials.
Testing at Huahui
We can carry out the UL 72 fire endurance test (section 6) on the vertical furnace at our Shanghai main laboratory. It is not currently within our CNAS / CMA accreditation, and reports carry no accreditation mark.
For the Chinese standard for safes, GB/T 16810, whose fire resistance test we can also carry out, see also our article GB/T 16810-2026, fire resistance requirements and test methods for safes, explained.
Available, not accredited
| Standard | Test items |
|---|---|
| UL 72 Fire resistance of record protection equipment (safes, file cabinets and similar) |
|
We can carry out these tests, but they are not currently within our CNAS / CMA accreditation, and reports carry no accreditation mark. If the results are for certification, check first that your certifier accepts them.
Frequently asked questions
Can you carry out the impact and explosion tests of UL 72?
What we list is the fire endurance test. For the fire and impact test (9.1 m drop), the explosion test and the combined explosion impact test, ask our engineers first.
Can the report be used for UL certification?
The certification body decides whether to accept test data. This test is not within our accreditation, so check with your certifier before placing the order.