Other fire-resistant products

GB/T 16810

GB/T 16810-2026 Tests and requirements for fire resistance of safe cases (《保险柜耐火性能要求和试验方法》), replacing GB/T 16810-2006

GB/T 16810 is China's recommended national standard for the fire resistance of safes: whether a safe protects the paper documents, storage devices and other items inside it in a fire. The 2026 edition took effect on 1 October 2026. We can carry out its fire resistance test; it is not currently within our accreditation.

Available, outside accreditation scope We can carry out the GB/T 16810 fire resistance test (chapter 8). It is not currently within our CNAS / CMA accreditation, and reports carry no accreditation mark.

What it tests

What matters in a fire is whether the contents of the safe are still usable. GB/T 16810-2026 has three classes by contents:

ClassInterior limitsTypical contents
HNot above 177 ℃Paper documents, photographs, paintings and calligraphy
MNot above 52 ℃ and 80 % relative humidityMemory cards, USB drives, computer storage devices
QNot above the manufacturer's declared values, and in any case not above 177 ℃ and 80 % relative humidityDefined by the manufacturer

Ratings are 0.5, 1.0, 1.5, 2.0, 3.0 or 4.0 hours. The time includes the cooling period after heating stops; the interior must stay within the limits during cooling too.

The tests:

  • Fire resistance test (chapter 8): exposure to the standard fire curve of GB/T 9978.1, measuring interior temperature and humidity, then checking that the contents are usable; a water impact test can be added.
  • Fire and drop test: two heating stages with a 9.1 m drop in between.
  • Sudden heating test: the specimen goes into a furnace brought to 1090 ± 5 ℃ within 10 minutes.
  • Combined sudden heating and fire and drop test.

For the changes in the 2026 edition, see our article GB/T 16810-2026, fire resistance requirements and test methods for safes, explained.

Testing at Huahui

We can carry out the GB/T 16810 fire resistance test (chapter 8) on the vertical furnace at our Shanghai main laboratory. It is not currently within our CNAS / CMA accreditation, and reports carry no accreditation mark. For products going to North America, see UL 72.

Available, not accredited

StandardTest items
GB/T 16810
Fire resistance requirements and test methods for safes
  • Fire resistance test (chapter 8)

We can carry out these tests, but they are not currently within our CNAS / CMA accreditation, and reports carry no accreditation mark. If the results are for certification, check first that your certifier accepts them.

Frequently asked questions

Can you carry out the fire and drop, sudden heating and combined tests?

What we list is the fire resistance test. For the fire and drop test (9.1 m drop), the sudden heating test and the combined sudden heating and fire and drop test, ask our engineers first.

How does GB/T 16810 relate to UL 72?

GB/T 16810-2006 was a modified adoption of UL 72:2001, and the approach is the same: expose the safe to the standard fire curve and check that the interior temperature stays below a limit for a set time, cooling period included. UL 72 is the reference for North America, GB/T 16810 for China.

Talk to an engineer

Tell us what you need to test

Describe the product, target market and standards. An engineer will get back to you shortly.