What it measures
With the door leaf open, a specified vertical load is applied at the end furthest from the hinges. The deformation of the leaf is measured under load and after unloading, to check whether the leaf sags and whether the door still opens and closes normally. This shows how reliable the hinges and the connections between frame and leaf will be in long-term use.
How it relates to the fire door standard
GB 12955-2024 lists resistance to vertical load as a test item for fire doors (clause 7.7.2), and this standard is the test method. The same group of mechanical tests also includes resistance to static torsion (GB/T 29530) and resistance to soft heavy body impact (GB/T 14155).
Testing at Huahui
Tests run at our Shanghai main laboratory. This test can be done on the same batch of samples as the fire door's fire resistance, opening and closing durability and other items.
Our accredited scope
| Accreditation | Standard | Test items |
|---|---|---|
| CNAS | GB/T 29049-2012 Doorsets — Vertical load test |
|
| CMA | GB/T 29049-2012 Doorsets — Vertical load test |
|
From our CNAS accreditation scope and our CMA approval (China's mandatory approval for inspection and testing bodies, needed for reports used in mainland China), as of 2026-10. Items not listed are outside the scope; ask our engineers whether they can be tested.