What it tests
Windows and doors are opened and closed every day, wearing hinges, locks, closers and seals. EN 1191 reproduces this with a test rig: the specimen is installed as in use and, starting closed and locked, the fastening is released, the leaf opened to the set position, closed and locked again. That is one cycle, repeated until the set number is reached or the product fails.
Key test conditions:
- Speed: the reference speed for manual operation depends on the leaf mass and type of movement (sliding, rotating, tilting), with a ±10 % tolerance. A rotating leaf of up to 65 kg, for example, moves at 0.50 m/s.
- Time: each manual operation of the leaf takes 1 to 4 seconds.
- Force: the force applied to the fastening system does not exceed 150 % of the last measured operating force, measured to EN 12046-1 (windows) or EN 12046-2 (doors).
- Number of cycles: classified to EN 12400 for mechanical durability, or to EN 14600 for fire and smoke door assemblies.
The details for each type are in the annexes: Annexes A–G for windows, Annex H for non-powered hinged pedestrian doors, Annex I for powered hinged pedestrian doors.
Testing at Huahui
We can carry out the test on non-powered hinged single- and double-leaf pedestrian door assemblies, including self-closing fire doors (Annex H), with a 6-axis industrial robot on a 2.5 m rail opening and closing the door, at our Shanghai main laboratory. It is not currently within our CNAS / CMA accreditation, and reports carry no accreditation mark.
For the fire resistance of fire doors for Europe, see EN 1634-1.
Available, not accredited
| Standard | Test items |
|---|---|
| EN 1191:2012 Windows and doors — Resistance to repeated opening and closing — Test method |
|
We can carry out these tests, but they are not currently within our CNAS / CMA accreditation, and reports carry no accreditation mark. If the results are for certification, check first that your certifier accepts them.
Frequently asked questions
Can you test windows, sliding doors or powered doors?
What we list is Annex H: non-powered hinged single- and double-leaf pedestrian doors, including self-closing fire doors. For windows (Annexes A–G) and powered hinged doors (Annex I), ask our engineers first.
How does it differ from the Chinese fire door durability test?
The repeated opening and closing durability test of GB 12955-2024 is within our CNAS accreditation. EN 1191 sets different speed, rhythm and force conditions: the reference speed comes from a table by leaf mass with a ±10 % tolerance, each manual operation takes 1 to 4 seconds, and the force on the fastening system is measured to EN 12046. Doors for Europe need a separate EN 1191 test.