Chinese standards: fire doors, windows, shutters and glass

GB/T 7106

GB/T 7106-2019 Test methods for air permeability, watertightness and wind load resistance of external windows and doors of buildings (《建筑外门窗气密、水密、抗风压性能检测方法》)

GB/T 7106 specifies test methods for the air permeability, watertightness and wind load resistance of external windows and doors of buildings. Huahui uses it to test these three properties of fire windows and other external windows. Clauses 7, 8 and 9 are within our CNAS accreditation, for windows smaller than 2400 mm × 2400 mm only.

Within CNAS accreditation Clauses 7, 8 and 9 of GB/T 7106-2019 are within our CNAS scope, for windows smaller than 2400 mm × 2400 mm only.

What it measures

The specimen is mounted on a pressure chamber, and three properties are tested by applying positive and negative pressure:

  • Air permeability: the air leakage through the window at a specified pressure difference;
  • Watertightness: under water spray, with pressure raised in steps, the highest pressure at which the window does not leak;
  • Wind load resistance: the deflection of the frame members under wind load, and whether the window is damaged and still works properly after repeated pressure cycles and the safety test.

Fire windows used as external windows must meet these physical performance requirements as well as fire resistance.

Testing at Huahui

Tests run at our Shanghai main laboratory. The accreditation scope is limited to windows smaller than 2400 mm × 2400 mm. For the fire resistance of fire windows, see GB 16809.

Our accredited scope

AccreditationStandardTest items
CNAS GB/T 7106-2019
Test methods for air permeability, watertightness and wind load resistance of building external windows and doors
  • Air permeability and wind load resistance – Fire windows (cl. 7, 9; Only windows smaller than 2400 mm × 2400 mm)
  • Watertightness – Fire windows (cl. 8; Only windows smaller than 2400 mm × 2400 mm)
CMA GB/T 7106-2019
Test methods for air permeability, watertightness and wind load resistance of building external windows and doors
  • Air permeability, watertightness and wind load resistance (Up to 2400 mm × 2400 mm)

From our CNAS accreditation scope and our CMA approval (China's mandatory approval for inspection and testing bodies, needed for reports used in mainland China), as of 2026-10. Items not listed are outside the scope; ask our engineers whether they can be tested.