What it measures
Ordinary external doors and windows are not fire windows, but in some buildings the design codes require doors and windows in external walls to have a certain fire integrity, to slow the spread of flame up the façade. GB/T 38252 tests such doors and windows: the specimen is exposed to fire on a furnace, and the time for which it keeps its integrity (no sustained flaming, no through gaps or openings) is recorded.
It assesses integrity only, not insulation. Windows that need insulation should be tested as fire windows to GB 16809.
Testing at Huahui
Tests run at our Shanghai main laboratory.
Our accredited scope
| Accreditation | Standard | Test items |
|---|---|---|
| CNAS | GB/T 38252-2019 Test method for fire integrity of building doors and windows |
|
| CMA | GB/T 38252-2019 Test method for fire integrity of building doors and windows |
|
From our CNAS accreditation scope and our CMA approval (China's mandatory approval for inspection and testing bodies, needed for reports used in mainland China), as of 2026-10. Items not listed are outside the scope; ask our engineers whether they can be tested.